Please use this identifier to cite or link to this item: https://repositorio.ufjf.br/jspui/handle/ufjf/16188
Files in This Item:
File Description SizeFormat 
fernandafaragedacostafelipeferreira.pdf1.43 MBAdobe PDFView/Open
Type: Dissertação
Title: Estudo comparativo do comportamento biomecânico de incisivos centrais superiores restaurados com núcleo metálico fundido de diferentes comprimentos submetidos a forças ortodônticas
Author: Ferreira, Fernanda Farage da Costa Felipe
First Advisor: Vitral, Robert Willer Farinazzo
Referee Member: Campos, Marcio José da Silva
Referee Member: Tanaka, Orlando Motohiro
Resumo: O Núcleo Metálico Fundido (NMF) é um retentor intrarradicular utilizado na restauração de dentes submetidos ao tratamento endodôntico com pouco remanescente coronário que altera o seu comportamento biomecânico radicular. Este estudo buscou avaliar através do Método de Elementos Finitos, a distribuição de tensões provocadas por forças ortodônticas na raiz de dentes restaurados com NMF medindo 1/2 e 2/3 do comprimento radicular. Foram criados dois modelos de incisivos centrais restaurados com NMF que mediam 1/2 e 2/3 do comprimento da raiz. Após a criação da malha de elementos finitos, foram simuladas forças ortodônticas, vestibulolingual de 65 gf e uma mesiodistal de 70 gf, aplicadas paralelamente ao plano palatino, no slot do bráquete situado a 4mm da borda incisal. As tensões principais máximas e a distribuição qualitativa foram adquiridas no NMF e no remanescente radicular. A análise da distribuição de tensões na estrutura do NMF revelou valores de tensões mais elevados no comprimento igual a 2/3 da raiz nas duas aplicações de forças, sendo concentrado no terço médio da porção mesial para a força mesiodistal (13,750 x 10-1 MPa) e no terço médio da porção vestibular na força vestibulolingual (10,200 x 10-1 MPa). Entretanto, a análise da distribuição de tensões na raiz revelou valores mais elevados no modelo restaurado com NMF com ½ do tamanho da raiz nas duas aplicações de forças, sendo concentrado no terço cervical/médio da porção mesial para as forças mesiodistal (3,845 x 10-1 Mpa) e terço cervical da porção vestibular na força vestibulolingual (2,800 x 10-1 Mpa). Apesar de ter havido diferença nas tensões máximas entre os NMF de diferentes comprimentos, os valores encontrados, assim como a diferença entre os valores de tensão nos diferentes modelos, situam-se numa margem segura para o uso dos dois comprimentos de NMF em relação às forças empregadas nos tratamentos ortodônticos.
Abstract: The Cast Metal Post (CMP) is an intraradicular retainer used in the restoration of endodontically treated teeth with little coronal remnant that alters its root biomechanical behavior. To evaluate, through the Finite Element Method, the stress distribution caused by orthodontic forces in the root of teeth restored with CMP measuring 1/2 and 2/3 of the root length. Two models of central incisors restored with CMP measuring 1/2 and 2/3 of the root length were created. After creating the finite element mesh, a buccolingual orthodontic force of 65 gf and a mesiodistal orthodontic force of 70 gf were simulated and applied parallel to the palatal plane, in the bracket slot located 4mm from the incisal edge. The maximum principal stresses and the qualitative distribution were acquired in the CMP and in the root remnant. The analysis of the stress distribution in the CMP structure revealed both force applications resulted in higher stress values in the post whose length equals 2/3 of the root length, being concentrated in the middle third of the mesial portion for the mesiodistal force (13,750 x 10 -1 MPa ) and in the middle third of the buccal portion in the buccolingual force (10,200 x 10 -1 MPa). However, the analysis of the stress distribution in the root revealed higher values in the model restored with CMP with ½ of the root length in the two force applications, being concentrated in the cervical/middle third of the mesial portion for the mesiodistal forces (3.845 x 10 - 1 Mpa) and cervical third of the buccal portion at the buccolingual force (2,800 x 10 -1 Mpa). Although there was a difference in the maximum tensions between the CMP of different lengths, the values found, as well as the difference between the tension values in the different models, are located in a safe margin for the use of the two lengths of CMP in relation to the forces used in orthodontic treatments.
Keywords: Análise de elementos finitos
Técnica para retentor intrarradicular
Técnicas de movimentação dentária
CNPq: CNPQ::CIENCIAS DA SAUDE
Language: por
Country: Brasil
Publisher: Universidade Federal de Juiz de Fora (UFJF)
Institution Initials: UFJF
Department: Faculdade de Medicina
Program: Programa de Pós-graduação em Saúde Brasileira
Access Type: Acesso Aberto
Attribution-NonCommercial-NoDerivs 3.0 Brazil
Creative Commons License: http://creativecommons.org/licenses/by-nc-nd/3.0/br/
URI: https://repositorio.ufjf.br/jspui/handle/ufjf/16188
Issue Date: 25-Sep-2023
Appears in Collections:Mestrado em Saúde (Dissertações)



This item is licensed under a Creative Commons License Creative Commons